• Deutschde
  • Englischen (selected)
Bookmarks (0)
Logo
!app ghielmetti theme default navtoggle label
  • Products
    • Media
      • Accessories
      • Channel Switch
      • Patchbay Audio
      • Impedance Converter / Splitter
      • Crossbars
      • Monitoring
      • Accessories Video
      • Patchbay Video
    • Industrial (selected)
      • Accessories
      • Channel Switchs
      • Analyzer
    • HPL Panels
  • News
    • News
    • Show
    • Press release
  • Company
    • History
    • Team
    • Documents
    • Jobs and Career
    • References
  • Service & Support
    • Customer Service
    • Contact form
    • Product Catalogue
    • Downloads
  • Products
    • Media
      • Accessories
      • Channel Switch
      • Patchbay Audio
      • Impedance Converter / Splitter
      • Crossbars
      • Monitoring
      • Accessories Video
      • Patchbay Video
    • Industrial (selected)
      • Accessories
      • Channel Switchs
      • Analyzer
    • HPL Panels
  • News
    • News
    • Show
    • Press release
  • Company
    • History
    • Team
    • Documents
    • Jobs and Career
    • References
  • Service & Support
    • Customer Service
    • Contact form
    • Product Catalogue
    • Downloads

 

Industrial
  • Accessories
  • Channel Switchs
  • Analyzer

Tripping matrix to Generator Protection Systems

gkv_10x32_621_sk_r_eldp.jpg

32 Input lines (columns), 32 Input discontinuity "E", 32 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 10 Output lines (rows), 2 rows Pin park, Input- and Output signalling by LED indication (red) "L", Storing of LED indication by latching relays, Group memory for storing of outgoing tripping signals, LED-Reset push button, LED-Test push button, integrated test unit for diode plugs "D", 2 designation strips, Power supply 250 VDC +/- 20%, 19", 6U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.230.00
GKV 10x32 621 SK R ELDP

Tripping matrix to Generator Protection Systems

gkv_20x60_621_am_eldp.jpg

60 Input lines (vertical), 60 Input discontinuity "E", 60 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 20 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red) "L", Storing of LED indication by solid state memory, Group memory for storing of tripping signals, LED-Reset push button with remote access, LED-Test push button remote access, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 6U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.420.00
GKV 20x60 621 AM ELDP

Tripping matrix to Generator Protection Systems

Front

15 Input lines (vertical), 15 Input discontinuity "E", 15 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 15 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red) "L", Storing of LED indication by solid state memory, Group memory for storing of tripping signals, LED-Reset push button with remote access, LED-Test push button remote access, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 5U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.410.20
GKV 15x15 621 AM ELDP 250 VDC

Diode plug, type 621

gds_621_20_zs_rt.jpg

handle length 20mm, red, row "Z"=anode, column "S"=cathode, Vrmax=1000V, If=1A

674.212.002.02
GDS 621/20 ZS rt

Matrix Board, type 621

Picture

31x31 In-/Output, 1-pole, Signal max.: 230VAC/16A, Frontpanel grey with black print, HxWxD: 258x258x39mm, solder lugs

674.110.039.02
GKV 31x31 621 LA

GKV 2x31x15 621 LA K, 2 Signal Distributors 220V/16A, on 1 front panel, 19"/6RU

31x15 Ein-/Ausgänge, 1-polige Durchschaltung, 15 Glimmlampen Typ T5.5 230V/1.5mA, horizontal, 31 Glimmlampen Typ T5.5 230V/1.5mA,vertikal links, 19"/6HE, Frontplatte grau mit alphanumerischem Druck, zusätzlich 4 Bezeichnungsstreifen, Lötanschlusstechnik

674.115.191.00
GKV 2x31x15 621 LA

Tripping matrix to Generator Protection Systems

gkv_20x60_621_am_ealdp.jpg

60 Input lines (vertical), 60 Input discontinuity "E", 60 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 20 Output lines (horizontal), 20 Output discontinuity "A", 20 connecting plugs GSS-621/15 rt red, 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red) "L", Storing of LED indication by solid state memory, Group memory for storing of tripping signals, LED-Reset push button with remote access, LED-Test push button remote access, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 6U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.420.15
GKV 20x60 621 AM EALDP

Tripping matrix to Generator Protection Systems

gkv_20x60_621_am_eealdp.jpg

60 Input lines (vertical), 60 Input discontinuity "E", 60 connecting plugs GSS-621/15 rt, red, 674.310.180.02, Input signal tap after input tap discontinuity "Ea", 60 connecting plugr GSS-621/15 rt red, for input tap discontinuity, 20 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red), Storing of LED indication by solid state memory "L", group memory for storing of tripping signals, LED-Reset push button, LED-Test push button, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 6 U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.420.05
GKV 20x60 621 AM EEaLDP

Tripping matrix to Generator Protection Systems

gkv_24x15_621_sk_r_k.jpg

24 Input lines (vertical), 24 Input discontinuity "E", 24 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 15 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red) "L", Storing of LED indication by latching relays, Group memory for storing of outgoing tripping signals, LED-Reset push button, LED-Test push button, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 5U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.210.00
GKV 24x15 621 SK R ELDP

Tripping matrix to Generator Protection Systems

gkv_32x15_621_sk_r_k_674.115.192.00_neu.jpg

32 Input lines (vertical), 32 Input discontinuity "E", 32 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 15 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red), Storing of LED indication by latching relays "L", Group memory for storing of outgoing tripping signals, LED-Reset push button, LED-Test push button, Power supply 250 VDC +/- 20%, Power supply monitoring, 19", 5U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.192.01
GKV 32x15 621 SK R ELDP

Tripping matrix to Generator Protection Systems

45 Input lines (vertical), 45 Input discontinuity, 45 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 15 Output lines (horizontal), 1-pole interconnection with diode plugs, 2 rows as pin park for 90 plugs, Power supply 240 VDC, 19", 4 RU, front panel grey, with plexiglas protection to be opened to the bottom, screw type terminals, 2 designation strips

674.115.270.00
GKV 15x45 621 SK EP

Tripping matrix to Generator Protection Systems,

gkv_10x30_621_am_eealdp_24v.jpg

30 Input lines (vertical), 30 Input discontinuity "E", 30 connecting plugs GSS-621/15 rt, red, 674.310.180.02, 30 Input signal tap after input tap discontinuity "Ea", 30 connecting plugs GSS-621/15 rt red, for input tap discontinuity, 10 Output lines (horizontal), 1-pole interconnection with diode plugs, integrated test unit for diode plugs "D", Pin park, Input- and Output signalling by LED indication (red), Storing of LED indication by solid state memory "L", group memory for storing of tripping signals, LED-Reset push button, LED-Test push button, Power supply 110 VDC +/- 20%, Power supply monitoring, 19", 6 U rack, front panel grey A281, dorsal screw mount connectors, max. 4mm2 wire, Acryl front cover, opening to the right "P"

674.115.420.32
GKV 10x30 621 AM EEaLDP 110VDC
Ghielmetti Solutions AG
Hauptsitz
Industriestrasse 6
CH-4562 Biberist
Schweiz
Tel: +41 32 671 13 13
Fax:
info@ghielmetti.ch
 
  • Information privacy
  • Imprint
  • GTC
to top

Diese Seite verwendet Cookies

OK